Swimming Pool Electromechanical Works, Plant Rooms & Control Panels
Engineering and assembling circulation pumps, sand filters, IP65 electrical control boards, 12V underwater LED lighting, and commissioning.

Integrated electromechanical plant room assembled by My Pools engineers with digital control systems
Why Choose My Pools for Mechanical Plant Rooms & Certified Electrical Safety?
The electromechanical plant room is the beating heart of any swimming pool and the most critical zone for bather safety where water and electricity intersect. Improvised wiring without differential earth-leakage protection is unacceptable.
My Pools engineers electromechanical systems strictly to IEC 60364-7-702 aquatic electrical safety codes: powering all underwater LED lights via isolated 12V safety transformers located outside the wet zone, equipping IP65 panels with 30mA RCD breakers, and laying out pumps and filters with clear maintenance access.
Certified Engineering & Warranty
Compliant with International & Egyptian Codes
- On-site inspection and survey before issuing final BOQ.
- Approved executive Shop Drawings for all networks.
- Original equipment with certificates of origin & warranty.
- Formal handover after pressure and commissioning tests.
The 5 Core Electromechanical Elements in Pool Commissioning
From the integrated plant room to pump-filter pairing, electrical switchgear, 12V lighting, and test-run commissioning.

Ergonomic Layout of Pumps, Filters & Treatment Units
Elevated pump plinths, forced ventilation, and sump drainage protecting motors from moisture.
Safety & Quality Standards in Electromechanical Execution
Zero-Compromise Electrical Safety & Earthing
Equipotential bonding of all ladders, pumps, and heaters to a tested earth grid with 30mA RCD trip protection.
- Safety isolating transformers (220V to 12V) for pool lights
- Phase failure and phase sequence protection relays
- Schneider / ABB circuit breakers and contactors
Plant Room Ventilation & Flood Prevention
Preventing motor burnout and board corrosion inside underground pump rooms via ventilation and sump pumps.
- Intake/exhaust fans removing motor heat and vapor
- Automated sump pump pit preventing plant room flooding
- Raised concrete plinths with rubber vibration pads
Systematic Testing, Balancing & Handover
Running the complete mechanical and electrical plant for 48 hours to log pressures, temperatures, and amps.
- Initial media backwash and pressure gauge calibration
- Seasonal timer scheduling for summer/winter cycles
- Laminated schematic diagram and numbered valve tags
Real Projects Featuring This Engineering Service
Major Athletic Complex · El Obour CityObour City Club – Integrated Multi-Pool Athletic Complex
City Club – El Obour City, Greater Cairo
ClearWater Ionization (-90% Chlorine) · OrabiClearWater Enviro Ionization System – Semi-Olympic Palace Pool, Orabi El Obour
Private Residential Palace · Orabi Association – El Obour City, Egypt
Flagship Coastal Resort · El GounaMangroovy Beach – Luxury Resort Swimming Pools & Interactive Water Features
El Gouna – Hurghada – Red Sea, Egypt
FAQs About Mechanical Plant Rooms & Certified Electrical Safety
Get a Technical Study & Accurate BOQ for Mechanical Plant Rooms & Certified Electrical Safety
Our engineering team is ready to inspect your site and deliver an optimal technical proposal.